




































The Maxillofacial Implant Mid 1.5 mm System by Siora Surgicals Pvt. Ltd. is designed to address delicate facial bone fractures with precision and stability. Crafted from high-quality medical-grade titanium, these implants ensure reliable fixation while maintaining a low-profile design for better patient comfort and aesthetics. The 1.5mm maxillofacial plate system includes a versatile range of plates and screws, allowing surgeons to adapt easily to varied clinical needs. Its accurate fit and smooth finish support quicker healing and reduced tissue irritation. Ideal for midface procedures, this CMF plate system 1.5 mm titanium, reflects Siora’s commitment to consistent quality, performance, and surgical ease.
Developed for accurate adaptation to midfacial anatomy, ensuring stable fixation and dependable surgical outcomes.
The 1.5 mm maxillofacial plate system is manufactured using medical-grade titanium for strength, durability, and biocompatibility.
Slim plate design minimizes palpability and enhances patient comfort while supporting better aesthetic results.
Includes a wide range of maxillofacial plates and screws to suit different fracture patterns and surgical requirements.
Polished edges help reduce soft tissue irritation and support improved healing conditions.
Ensures firm stability in delicate bone structures, allowing proper alignment and faster recovery.
Used for stabilizing fractures in the midfacial region, ensuring proper alignment and healing.
Ideal for repairing fractures around the orbital rim while maintaining structural integrity and contour.
Provides reliable fixation in nasal bone fractures to restore form and function.
Helps in the effective management of zygomatic bone injuries with stable and secure fixation.
This CMF mid 1.5mm system is suitable for treating fractures of the maxilla, ensuring accurate repositioning of bone segments.
Used in reconstructive surgeries to restore facial symmetry and support anatomical structure.
We manufacture 1.5 mm-thick maxillofacial implants in different structural configurations to suit different fracture patterns and patient anatomies. Moreover, we also offer CMF screws in different lengths and diameters compatible with our midface locking plate system 1.5 mm.
The locking straight plate 1.5mm provides rigid fixation for linear fractures with a locking mechanism, ensuring stability, precise alignment, and reduced risk of screw loosening.
| Cat No. | Thickness (mm) | Holes | Length (mm) |
| Ti.850.301 – Ti.850.304 | 1.5 | 6 – 16 | 35 – 95 |
Designed to bridge comminuted fractures, the locking straight bridge plate maintains bone length and alignment while offering strong, stable fixation across fragmented segments.
| Cat No. (Titanium) | Dia (mm) | Length (mm) |
| Ti.610.55.30 – Ti.610.55.50 | 5.5 | 30-50 * |
| Ti.610.65.30 – Ti.610.65.50 | 6.5 | 30-50 * |
| Ti.610.75.30 – Ti.610.75.50 | 7.5 | 30-50 * |
* Available in diameters ranging from 30mm to 50mm (with a difference of 5mm).
The curved design of this locking arc bridge plate adapts to facial contours, ideal for bridging fractures while ensuring even load distribution and improved anatomical fit.
| Cat No. | Thickness (mm) | Holes | Length (mm) |
| Ti.850.315 – Ti.850.316 | 1.5 | 4 – 6 | 29 – 40 |
Pre-shaped 120° locking arc plate ensures optimal adaptation in curved anatomical regions, delivering secure fixation and enhanced surgical convenience.
| Cat No. | Thickness (mm) | Holes | Length (mm) |
| Ti.850.320 – Ti.850.321 | 1.5 | 6 – 8 | 36 – 46 |
Offers multidirectional stability for complex fractures, with a rectangular shape and multiple locking holes providing balanced fixation and support across wider bone surfaces.
| Cat No. | Thickness (mm) | Holes | Length (mm) |
| Ti.850.330 – Ti.850.332 | 1.5 | 8 – 16 | 25 – 51 |
T-shaped configuration supports fracture fixation in intersecting bone regions, ensuring stability and ease during reconstructive procedures.
| Cat No. | Thickness (mm) | Holes | Length (mm) |
| Ti.850.340 – Ti.850.341 | 1.5 | 5 – 7 | 19 – 31 |
The right-angled locking L-plate is designed for corner fractures, offering firm fixation and precise support in perpendicular anatomical structures.
| 4 Holes | |||
| Cat No. (Left) | Thickness (mm) | Length (mm) | Cat No. (Right) |
| Ti.850.343 – Ti.850.344 | 1.5 mm | 20, 24 | Ti.850.345 – Ti.850.346 |
110° angled L-plate adapts to varied anatomical contours, ensuring secure fixation and flexibility in complex fracture management.
| Thickness 1.5 mm | |||
| Cat No. (Left) | Holes | Length (mm) | Cat No. (Right) |
| Ti.850.348 – Ti.850.350 | 4, 5, 7 | 19, 25, 31 | Ti.850.351 – Ti.850.353 |
The cross-shaped design of the locking X-plate provides multi-directional stability, ideal for central fracture zones requiring balanced and secure fixation.
| Cat No. | Thickness | Holes | Length |
| Ti.850.355 | 1.5 mm | 4 | 17 mm |
Double Y configuration enhances stability in complex fractures, supporting multiple fixation points for improved load distribution.
| Cat No. | Thickness | Holes | Length |
| Ti.850.360 | 1.5 mm | 6 | 23 mm |
The Locking Y- plate allows effective fixation in branching fracture patterns, ensuring stability and anatomical alignment.
| Cat No. | Thickness (mm) | Holes | Length (mm) |
| Ti.850.365 – Ti.850.366 | 1.5 | 6 – 7 | 30 – 36 |
The locking H-plate offers strong support across parallel fracture lines, improving stability and maintaining structural integrity.
| Cat No. | Thickness (mm) | Holes | Length (mm) |
| Ti.850.370 – Ti.850.373 | 1.5 | 7, 11, 15, 19 | 17, 29, 41, 53 |
Self-tapping locking screw ensures secure fixation, reduces surgical steps, and provides a strong hold within bone structures.
| Cat No. | Length (mm) |
| Ti.126.105 – Ti.126.113 | 5.5, 7, 9, 11, 13 |
Cat No. XP.916.105 – CMF Drill Bit – Plain Shank Dia. 1.6mm x 12mm x 48mm Long to be use with all 2.2mm Locking & Non Locking Screws
Non-locking self-tapping screw allows easy insertion, offering reliable compression and fixation in various maxillofacial applications.
| Cat No. | Length (mm) |
| Ti.126.205 – Ti.126.213 | 5.5, 7, 9, 11, 13 |
Cat No. XP.916.105 – CMF Drill Bit – Plain Shank Dia. 1.6mm x 12mm x 48mm Long to be use with all 2.2mm Locking & Non Locking Screws
Self-drilling screw eliminates pre-drilling, simplifying procedures while ensuring firm fixation and reducing operative time.
| Cat No. | Length (mm) |
| Ti.126.305 – Ti.126.311 | 5, 6, 7, 9, 11 |
Cat No. XP.916.105 – CMF Drill Bit – Plain Shank Dia. 1.6mm x 12mm x 48mm Long to be use with all 2.2mm Locking & Non Locking Screws
Designed for emergency use, provides quick and secure fixation in critical situations requiring immediate stabilization.
| Cat No. | Length (mm) |
| Ti.126.406 – Ti.126.414 | 6, 7 , 8 , 9, 11, 13, 14 |
The non-locking emergency screw 2.3mm Dia. ensures rapid application in urgent cases, delivering dependable fixation without locking mechanism support.
| Cat No. | Length (mm) |
| Ti.126.506 – Ti.126.514 | 6, 7 , 8 , 9, 11, 13, 14 |
The mid 1.5mm low-profile plate system containing a wide range of CMF plates ensures precise fixation in midface surgeries, offering strength, adaptability, and compatibility with 2.0 mm screws.
| IS.203 | MID MAXILLOFACIAL PLATE (1.5MM THICKNESS) 2.0MM SCREWS SYSTEM | Units |
|---|---|---|
| TI.850.301 | CMF – Locking Straight Plate (Thickness 1.5MM) 6 Holes Length 35MM -Titanium | 1 |
| TI.850.302 | CMF – Locking Straight Plate (Thickness 1.5MM) 8 Holes Length 47MM -Titanium | 1 |
| TI.850.303 | CMF – Locking Straight Plate (Thickness 1.5MM) 12 Holes Length 71MM -Titanium | 1 |
| TI.850.304 | CMF – Locking Straight Plate (Thickness 1.5MM) 16 Holes Length 95MM -Titanium | 1 |
| TI.850.310 | CMF – Locking Straight Bridge Plate (Thickness 1.5MM) 4 Holes Length 29MM -Titanium | 1 |
| TI.850.311 | CMF – Locking Straight Bridge Plate (Thickness 1.5MM) 6 Holes Length 41MM -Titanium | 1 |
| TI.850.315 | CMF – Locking Arc Bridge Plate (Thickness 1.5MM) 4 Holes Length 29MM -Titanium | 1 |
| TI.850.316 | CMF – Locking Arc Bridge Plate (Thickness 1.5MM) 6 Holes Length 40MM -Titanium | 1 |
| TI.850.320 | CMF – Locking Arc Plate 120°Deg. (Thickness 1.5MM) 6 Holes Length 36MM -Titanium | 1 |
| TI.850.321 | CMF – Locking Arc Plate 120°Deg. (Thickness 1.5MM) 8 Holes Length 46MM -Titanium | 1 |
| TI.850.330 | CMF – Locking Rectangle Plate (Thickness 1.5MM) 8 Holes Length 25MM -Titanium | 1 |
| TI.850.331 | CMF – Locking Rectangle Plate (Thickness 1.5MM) 12 Holes Length 38MM -Titanium | 1 |
| TI.850.332 | CMF – Locking Rectangle Plate (Thickness 1.5MM) 16 Holes Length 51MM -Titanium | 1 |
| TI.850.340 | CMF – Locking T- Plate (Thickness 1.5MM) 5 Holes Length 19MM -Titanium | 1 |
| TI.850.341 | CMF – Locking T- Plate (Thickness 1.5MM) 7 Holes Length 31MM -Titanium | 1 |
| TI.850.343 | CMF – Locking L-Plate 90°Deg. (Thickness 1.5MM) 4 Holes Length 20MM – Left – Titanium | 1 |
| TI.850.344 | CMF – Locking L-Plate 90°Deg. (Thickness 1.5MM) 4 Holes Length 24MM – Left – Titanium | 1 |
| TI.850.345 | CMF – Locking L-Plate 90°Deg. (Thickness 1.5MM) 4 Holes Length 20MM – Right- Titanium | 1 |
| TI.850.346 | CMF – Locking L-Plate 90°Deg. (Thickness 1.5MM) 4 Holes Length 24MM -Right – Titanium | 1 |
| TI.850.348 | CMF – Locking L-Plate 110°Deg. (Thickness 1.5MM) 4 Holes Length 19MM – Left -Titanium | 1 |
| TI.850.349 | CMF – Locking L-Plate 110°Deg. (Thickness 1.5MM) 5 Holes Length 25MM – Left -Titanium | 1 |
| TI.850.350 | CMF – Locking L-Plate 110°Deg. (Thickness 1.5MM) 7 Holes Length 31MM – Left -Titanium | 1 |
| TI.850.351 | CMF – Locking L-Plate 110°Deg. (Thickness 1.5MM) 4 Holes Length 19MM – Right – Titanium | 1 |
| TI.850.352 | CMF – Locking L-Plate 110°Deg. (Thickness 1.5MM) 5 Holes Length 25MM – Right – Titanium | 1 |
| TI.850.353 | CMF – Locking L-Plate 110°Deg. (Thickness 1.5MM) 7 Holes Length 31MM – Right – Titanium | 1 |
| TI.850.355 | CMF – Locking X – Plate (Thickness 1.5MM) 4 Holes Length 17MM -Titanium | 1 |
| TI.850.360 | CMF – Locking Double Y- Plate (Thickness 1.5MM) 6 Holes Length 23MM -Titanium | 1 |
| TI.850.365 | CMF – Locking Y- Plate (Thickness 1.5MM) 6 Holes Length 30MM -Titanium | 1 |
| TI.850.366 | CMF – Locking Y- Plate (Thickness 1.5MM) 7 Holes Length 36MM -Titanium | 1 |
| TI.850.370 | CMF – Locking H- Plate (Thickness 1.5MM) 7 Holes Length 17MM -Titanium | 1 |
| TI.850.371 | CMF – Locking H- Plate (Thickness 1.5MM) 11 Holes Length 29MM -Titanium | 1 |
| TI.850.372 | CMF – Locking H – Plate (Thickness 1.5MM) 15Holes Length 41MM -Titanium | 1 |
| TI.850.373 | CMF – Locking H – Plate (Thickness 1.5MM) 19 Holes Length 53MM -Titanium | 1 |
| Ti.126.105 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.0mm Length 5.5mm -Titanium | 10 |
| Ti.126.107 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.0mm Length 7mm -Titanium | 10 |
| Ti.126.109 | CMF – Cross Drive LOCKING Screw -Self Tapping – Dia 2.0mm Length 9mm -Titanium | 10 |
| Ti.126.111 | CMF – Cross Drive LOCKING Screw -Self Tapping – Dia 2.0mm Length 11mm -Titanium | 10 |
| Ti.126.113 | CMF – Cross Drive LOCKING Screw -Self Tapping – Dia 2.0mm Length 13mm -Titanium | 10 |
| Ti.126.205 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.0mm Length 5.5mm -Titanium | 10 |
| Ti.126.207 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.0mm Length 7mm -Titanium | 10 |
| Ti.126.209 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.0mm Length 9mm -Titanium | 10 |
| Ti.126.211 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.0mm Length 11mm -Titanium | 10 |
| Ti.126.213 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.0mm Length 13mm -Titanium | 10 |
| TI.126.305 | CMF – Cross Drive NON Locking Screw – Self Drilling – Dia 2.0mm Length 5mm -Titanium | 10 |
| TI.126.306 | CMF – Cross Drive NON Locking Screw – Self Drilling – Dia 2.0mm Length 6mm -Titanium | 10 |
| TI.126.307 | CMF – Cross Drive NON Locking Screw – Self Drilling – Dia 2.0mm Length 7mm -Titanium | 10 |
| TI.126.309 | CMF – Cross Drive NON Locking Screw – Self Drilling – Dia 2.0mm Length 9mm -Titanium | 10 |
| TI.126.311 | CMF – Cross Drive NON Locking Screw – Self Drilling – Dia 2.0mm Length 11mm -Titanium | 10 |
| Ti.126.406 | CMF – Locking EMERGENCY Screw – Dia 2.3mm Length 6mm -Titanium | 10 |
| Ti.126.407 | CMF – Locking EMERGENCY Screw – Dia 2.3mm Length 7mm -Titanium | 10 |
| Ti.126.408 | CMF – Locking EMERGENCY Screw – Dia 2.3mm Length 8mm -Titanium | 10 |
| Ti.126.409 | CMF – Locking EMERGENCY Screw – Dia 2.3mm Length 9mm -Titanium | 10 |
| Ti.126.411 | CMF – Locking EMERGENCY Screw – Dia 2.3mm Length 11mm -Titanium | 10 |
| Ti.126.413 | CMF – Locking EMERGENCY Screw – Dia 2.3mm Length 13mm -Titanium | 10 |
| Ti.126.414 | CMF – Locking EMERGENCY Screw – Dia 2.3mm Length 14mm -Titanium | 10 |
| Ti.126.506 | CMF – NON Locking EMERGENCY Screw – Dia 2.3mm Length 6mm -Titanium | 10 |
| Ti.126.507 | CMF – NON Locking EMERGENCY Screw – Dia 2.3mm Length 7mm -Titanium | 10 |
| Ti.126.508 | CMF – NON Locking EMERGENCY Screw – Dia 2.3mm Length 8mm -Titanium | 10 |
| Ti.126.509 | CMF – NON Locking EMERGENCY Screw – Dia 2.3mm Length 9mm -Titanium | 10 |
| Ti.126.511 | CMF – NON Locking EMERGENCY Screw – Dia 2.3mm Length 11mm -Titanium | 10 |
| Ti.126.513 | CMF – NON Locking EMERGENCY Screw – Dia 2.3mm Length 13mm -Titanium | 10 |
| Ti.126.514 | CMF – NON Locking EMERGENCY Screw – Dia 2.3mm Length 14mm -Titanium | 10 |
| 400.173 | Implant Box for MID Maxillofacial Plate (1.5mm Thickness) 2.0mm Screws System (Medical Grade Plastic) | 1 |
The oral maxillofacial surgical instruments set by Siora Surgicals Pvt. Ltd. is designed with ergonomics and performance in mind. These CMF instruments are surgeon-friendly and easy to sterilize & maintain, making them suitable for repeated use. This comprehensive maxillofacial trauma instrument set is a dependable choice for modern maxillofacial surgeries.
| Cat No. IS.208 | Description | Units |
|---|---|---|
| XP.916.101 | CMF Straight Quick Coupling Handle | 1 |
| XP.916.102 | CMF Cross Drive Screw Driver Shaft | 1 |
| XP.916.103 | CMF Surgical Elevator 1.5mm Dia. | 1 |
| XP.916.104 | CMF Drill Bit – Plain Shank Dia. 1.1mm X 8.5mm X 48mm Long | 1 |
| XP.916.105 | CMF Drill Bit – Plain Shank Dia. 1.6mm X 12mm X 48mm Long | 1 |
| XP.916.106 | CMF Drill Bit – Plain Shank Dia. 1.9mm X 22mm X 58mm Long | 1 |
| XP.916.107 | CMF Drill Bit – Plain Shank Dia. 1.9mm X 57mm X 82mm Long | 1 |
| XP.916.108 | CMF Temporary Holder HC 2.4mm | 2 |
| XP.916.109 | CMF Universal Drill Guide 1.1/1.6mm | 1 |
| XP.916.110 | CMF Universal Drill Guide 1.6/1.9mm | 1 |
| XP.916.111 | CMF Depth Gauge | 1 |
| 916.120 | CMF Locking Drill Sleeve 1.9mm | 2 |
| 916.121 | CMF Plate Holding Forceps | 1 |
| 400.177 | Instrument Box for Maxillofacial Plating System (Medical Grade Plastic) | 1 |
The system includes a comprehensive range of titanium locking plates, such as straight plates, bridge plates, arc plates, L/T/Y/X/H configurations, along with compatible 2.0mm (locking and non-locking) and 2.3mm screws (Emergency screws). It is designed for midface trauma and reconstruction procedures.
The system is manufactured using medical-grade titanium, ensuring excellent biocompatibility, corrosion resistance, and long-term stability in cranio-maxillofacial applications.
The system includes multiple plate configurations:
Locking Straight Plate
Locking Straight Bridge Plate
Locking Arc Plate (120°)
Locking L-Plate (90° & 110°)
Locking T, Y, Double Y, X, and H Plates
Locking Rectangle Plate
These variations allow surgeons to address complex anatomical structures.
Yes, the system supports both locking and non-locking screws, including self-tapping and self-drilling variants, offering flexibility during surgical procedures.
The system primarily uses:
2.0 mm diameter screws (locking & non-locking)
2.3 mm emergency screws for intraoperative flexibility
Yes, the system is designed to meet international regulatory and quality requirements, making it suitable for distribution across Europe, Asia, Africa, and other global markets.
Yes, Siora Surgicals Pvt. Ltd. provides OEM and private labeling services for international distributors and importers.
MOQ depends on product type and customization requirements. Bulk orders for distributors and hospitals are supported with competitive pricing.
The system is supplied in sterile or non-sterile packaging, with organized implant trays and labeling in accordance with ISO 14644, suitable for export and hospital use.
Locking plates provide angular stability, reduce micro-movements, and improve fixation strength, especially in osteoporotic or thin facial bones.
Yes, customization options such as branding, kit configurations, and packaging are available for clients.
If you are interested in our products and want to know more details, please leave message here, we will reply you as soon as we can.