




















Siora Surgicals Pvt. Ltd. offers 2.4mm mandibular maxillofacial reconstruction implants designed to support effective restoration of jaw defects caused by trauma, tumor resection, or congenital conditions. Precision-crafted from high-quality, biocompatible titanium, these CMF locking reconstruction plates and screws ensure strength, stability, and long-term performance. Their anatomical design allows better contouring of the mandible, helping surgeons achieve accurate alignment during reconstruction procedures. Easy handling and secure fixation contribute to reduced surgical time and improved patient outcomes. Trusted by professionals, these mandibular maxillofacial reconstruction implants are developed to meet international standards, making them a reliable choice for complex maxillofacial reconstruction surgeries.
Manufactured using premium-grade titanium to ensure excellent strength, durability, and long-term biocompatibility.
Contoured to match the mandibular structure, these titanium mandibular pates allow for a precise fit and improved alignment during reconstruction procedures.
Provides the right balance of rigidity and flexibility for effective load-bearing support in complex cases.
Designed to work seamlessly with compatible screws, ensuring firm stabilization and reduced risk of implant failure.
Surgeon-friendly design of mandibular plates and screws enables convenient bending, placement, and adjustment, helping reduce surgical time.
This mandibular reconstruction plate system is suitable for a wide range of mandibular reconstruction cases, including trauma, tumor resection, and deformity correction, offering surgical flexibility.
Used to stabilize and restore jaw continuity in cases of complex fractures and traumatic bone loss.
Ideal for reconstructing mandibular defects following tumor removal, ensuring structural support and functional recovery.
Indicated for bridging large gaps in the mandible caused by injury, infection, or surgical excision.
Supports reconstruction in patients with developmental abnormalities affecting mandibular shape and function.
Useful in corrective procedures where previous implants or reconstructions have failed or require adjustment.
Provides reliable fixation after surgical cutting and repositioning of the jaw to restore alignment and function.
We manufacture maxillofacial reconstruction plates and screws in different sizes and types to ensure surgical precision and better patient outcomes. Our reconstruction plates are anatomically contoured for precise placement.
Rigid fixation plate designed for mandibular reconstruction, offering a stable locking mechanism, precise alignment, and reliable support in complex maxillofacial surgeries.
| Cat No. | Thickness | Holes | Length (mm) |
| Ti.850.401- Ti.850.407 | 2.4 mm | 8 – 20 * | 69 – 171 * |
* Available Holes ranging from 8 to 20 (with a difference of 2) and lengths ranging from 69mm to 171mm (with a difference of 17mm).
L-shaped locking reconstruction plate with 120° angle, ideal for mandibular contouring, providing enhanced stability and secure fixation in angular reconstruction procedures.
| Thickness 2.4 mm | |||
| Cat No. (Right) | Holes | Length (mm) | Cat No. (Left) |
| Ti.850.501 – Ti.850.504 | 13, 15, 19, 23 | 98, 115, 149, 183 | Ti.850.511 Ti.850.514 |
Anatomically contoured L-shaped reconstruction plate ensures better adaptation, minimizing bending time while delivering strong, stable fixation in mandibular reconstruction cases.
| Thickness 2.4 mm | |||
| Cat No. (Right) | Holes | Length (mm) | Cat No. (Left) |
| Ti.850.601 – Ti.850.603 | 12, 13, 14 | 132, 138, 142 | Ti.850.611 – Ti.850.613 |
CMF straight non-locking reconstruction plate is designed for versatile applications, offering dependable fixation and flexibility during mandibular reconstruction without locking screw mechanism.
| Cat No. | Thickness | Holes | Length (mm) |
| Ti.850.701 – Ti.850.707 | 2.4 mm | 8 – 20 * | 68 – 170 * |
* Available Holes ranging from 8 to 20 (with a difference of 2) and lengths ranging from 68mm to 170mm (with a difference of 17mm).
CMF L-shaped non-locking plate with 120° angle is suitable for contouring and stabilizing mandibular defects with ease and surgical flexibility.
| Thickness 2.4 mm | |||
| Cat No. (Right) | Holes | Length (mm) | Cat No. (Left) |
| Ti.850.801 – Ti.850.804 | 13, 15, 19, 23 | 97, 114, 148, 182 | Ti.850.811 – Ti.850.814 |
Titanium locking L reconstruction plate with 120° angulation for stable fixation of mandibular and midface fractures. Designed for anatomical contouring and rigid load-bearing support in craniomaxillofacial surgery.
| Thickness 2.4 mm | |||
| Cat No. (Right) | Holes | Length (mm) | Cat No. (Left) |
| Ti.850.601 – Ti.850.603 | 12, 13, 14 | 132, 138, 142 | Ti.850.611 – Ti.850.613 |
Titanium condyle block designed for use with anatomical L plates in Temporomandibular Joint reconstruction. Provides stable fixation and load distribution for condylar fractures and osteotomies in maxillofacial trauma and orthognathic procedures.
| Cat No. | Ti.850.901 |
Titanium fastening cap used to secure locking screws in maxillofacial plating systems. Ensures screw stability, prevents back-out, and maintains rigid fixation in craniofacial and mandibular reconstructive surgeries.
| Cat No. | Ti.127.500 |
This fastening screw, 2.5mm diameter, is used for maxillofacial fixation. Offers high pull-out strength and compatibility with locking plates, ensuring secure osteosynthesis in midface, mandibular, and orbital fracture management.
| Cat No. | Length (mm) |
| Ti.127.508 – Ti.127.512 | 8 – 12 |
The self-tapping cross-drive locking screw ensures firm fixation, reduces operative steps, and provides strong stability when used with compatible locking plates.
| Cat No. | Length (mm) |
| Ti.127.108 – Ti.127.120 | 8 – 20 * |
* Available Lengths ranging from 8mm to 20mm (with a difference of 2mm).
Cat No. XP.916.106 – CMF Drill Bit – Plain Shank Dia. 1.9mm x 22mm x 58mm Long Cat No. XP.916.107 – CMF Drill Bit – Plain Shank Dia. 1.9mm x 57mm x 82mm Long to be use with all 2.4mm Locking & Non Locking Screws
Non-locking self-tapping screw is designed for smooth insertion, ensuring reliable fixation and compatibility with standard reconstruction plates in CMF procedures.
| Cat No. | Length (mm) |
| Ti.127.208 – Ti.127.220 | 8 – 20 * |
* Available Lengths ranging from 8mm to 20mm (with a difference of 2mm).
Cat No. XP.916.106 – CMF Drill Bit – Plain Shank Dia. 1.9mm x 22mm x 58mm Long Cat No. XP.916.107 – CMF Drill Bit – Plain Shank Dia. 1.9mm x 57mm x 82mm Long to be use with all 2.4mm Locking & Non Locking Screws
Emergency locking screw 2.8mm dia. is designed for immediate intraoperative use, offering enhanced grip and stability in challenging or unexpected surgical situations.
| Cat No. | Length (mm) |
| Ti.127.308 – Ti.127.320 | 8 – 20 * |
Non-locking emergency screw provides a quick fixation solution, ensuring stability and adaptability during urgent adjustments in maxillofacial surgeries.
| Cat No. | Length (mm) |
| Ti.127.408 – Ti.127.420 | 8 – 20 * |
Comprehensive maxillofacial reconstruction plate system designed for mandibular defects, ensuring rigid fixation, anatomical adaptation, and compatibility with 2.4mm screws for optimal outcomes.
| IS.204 | MANDIBULAR MAXILLOFACIAL RECONSTRUCTION PLATE (2.4MM THICKNESS) 2.4MM SCREWS SYSTEM | Units |
|---|---|---|
| Ti.850.401 | CMF – Locking Straight Recontruction Plate (Thickness 2.4MM) 8 Holes Length 69MM -Titanium | 1 |
| Ti.850.402 | CMF – Locking Straight Recontruction Plate (Thickness 2.4MM) 10 Holes Length 86MM -Titanium | 1 |
| Ti.850.403 | CMF – Locking Straight Recontruction Plate (Thickness 2.4MM) 12 Holes Length 103MM -Titanium | 1 |
| Ti.850.404 | CMF – Locking Straight Recontruction Plate (Thickness 2.4MM) 14 Holes Length 120MM -Titanium | 1 |
| Ti.850.405 | CMF – Locking Straight Recontruction Plate (Thickness 2.4MM) 16 Holes Length 137MM -Titanium | 1 |
| Ti.850.406 | CMF – Locking Straight Recontruction Plate (Thickness 2.4MM) 18 Holes Length 154MM -Titanium | 1 |
| Ti.850.407 | CMF – Locking Straight Recontruction Plate (Thickness 2.4MM) 20 Holes Length 171MM -Titanium | 1 |
| Ti.850.501 | CMF – Locking L- Recontruction Plate 120°Deg. (Thickness 2.4MM) 13 Holes Length 98MM -Right -Titanium | 1 |
| Ti.850.511 | CMF – Locking L- Recontruction Plate 120°Deg. (Thickness 2.4MM) 13 Holes Length 98MM -Left -Titanium | 1 |
| Ti.850.502 | CMF – Locking L- Recontruction Plate 120°Deg. (Thickness 2.4MM) 15 Holes Length 115MM -Right -Titanium | 1 |
| Ti.850.512 | CMF – Locking L- Recontruction Plate 120°Deg. (Thickness 2.4MM) 15 Holes Length 115MM -Left -Titanium | 1 |
| Ti.850.503 | CMF – Locking L- Recontruction Plate 120°Deg. (Thickness 2.4MM) 19 Holes Length 149MM -Right -Titanium | 1 |
| Ti.850.513 | CMF – Locking L- Recontruction Plate 120°Deg. (Thickness 2.4MM) 19 Holes Length 149MM -Left -Titanium | 1 |
| Ti.850.504 | CMF – Locking L- Recontruction Plate 120°Deg. (Thickness 2.4MM) 23 Holes Length 183MM -Right -Titanium | 1 |
| Ti.850.514 | CMF – Locking L- Recontruction Plate 120°Deg. (Thickness 2.4MM) 23 Holes Length 183MM -Left -Titanium | 1 |
| Ti.850.701 | CMF – Straight Recontruction Plate (Thickness 2.4MM) 8 Holes Length 68MM -Titanium | 1 |
| Ti.850.702 | CMF – Straight Recontruction Plate (Thickness 2.4MM) 10 Holes Length 85MM -Titanium | 1 |
| Ti.850.703 | CMF – Straight Recontruction Plate (Thickness 2.4MM) 12 Holes Length 102MM -Titanium | 1 |
| Ti.850.704 | CMF – Straight Recontruction Plate (Thickness 2.4MM) 14 Holes Length 119MM -Titanium | 1 |
| Ti.850.705 | CMF – Straight Recontruction Plate (Thickness 2.4MM) 16 Holes Length 136MM -Titanium | 1 |
| Ti.850.706 | CMF – Straight Recontruction Plate (Thickness 2.4MM) 18 Holes Length 153MM -Titanium | 1 |
| Ti.850.707 | CMF – Straight Recontruction Plate (Thickness 2.4MM) 20 Holes Length 170MM -Titanium | 1 |
| Ti.850.801 | CMF – L- Recontruction Plate 120°Deg.(Thickness 2.4MM) 13 Holes Length 97MM – Right -Titanium | 1 |
| Ti.850.811 | CMF – L- Recontruction Plate 120°Deg. (Thickness 2.4MM) 13 Holes Length 97MM – Left -Titanium | 1 |
| Ti.850.802 | CMF – L- Recontruction Plate 120°Deg. (Thickness 2.4MM) 15 Holes Length 114MM – Right -Titanium | 1 |
| Ti.850.812 | CMF – L- Recontruction Plate 120°Deg. (Thickness 2.4MM) 15 Holes Length 114MM – Left -Titanium | 1 |
| Ti.850.803 | CMF – L- Recontruction Plate 120°Deg. (Thickness 2.4MM) 19 Holes Length 148MM – Right -Titanium | 1 |
| Ti.850.813 | CMF – L- Recontruction Plate 120°Deg. (Thickness 2.4MM) 19 Holes Length 148MM – Left -Titanium | 1 |
| Ti.850.804 | CMF – L- Recontruction Plate 120°Deg. (Thickness 2.4MM) 23 Holes Length 182MM – Right -Titanium | 1 |
| Ti.850.814 | CMF – L- Recontruction Plate 120°Deg. (Thickness 2.4MM) 23 Holes Length 182MM – Left -Titanium | 1 |
| Ti.127.108 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.4mm Length 8mm -Titanium | 10 |
| Ti.127.110 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.4mm Length 10mm -Titanium | 10 |
| Ti.127.112 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.4mm Length 12mm -Titanium | 10 |
| Ti.127.114 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.4mm Length 14mm -Titanium | 10 |
| Ti.127.116 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.4mm Length 16mm -Titanium | 10 |
| Ti.127.118 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.4mm Length 18mm -Titanium | 10 |
| Ti.127.120 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.4mm Length 20mm -Titanium | 10 |
| Ti.127.208 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.4mm Length 8mm -Titanium | 10 |
| Ti.127.210 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.4mm Length 10mm -Titanium | 10 |
| Ti.127.212 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.4mm Length 12mm -Titanium | 10 |
| Ti.127.214 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.4mm Length 14mm -Titanium | 10 |
| Ti.127.216 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.4mm Length 16mm -Titanium | 10 |
| Ti.127.218 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.4mm Length 18mm -Titanium | 10 |
| Ti.127.220 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.4mm Length 20mm -Titanium | 10 |
| Ti.127.308 | CMF – Locking EMERGENCY Screw – Dia 2.8mm Length 8mm -Titanium | 10 |
| Ti.127.310 | CMF – Locking EMERGENCY Screw – Dia 2.8mm Length 10mm -Titanium | 10 |
| Ti.127.312 | CMF – Locking EMERGENCY Screw – Dia 2.8mm Length 12mm -Titanium | 10 |
| Ti.127.314 | CMF – Locking EMERGENCY Screw – Dia 2.8mm Length 14mm -Titanium | 10 |
| Ti.127.316 | CMF – Locking EMERGENCY Screw – Dia 2.8mm Length 16mm -Titanium | 10 |
| Ti.127.318 | CMF – Locking EMERGENCY Screw – Dia 2.8mm Length 18mm -Titanium | 10 |
| Ti.127.320 | CMF – Locking EMERGENCY Screw – Dia 2.8mm Length 20mm -Titanium | 10 |
| Ti.127.408 | CMF – NON Locking EMERGENCY Screw – Dia 2.8mm Length 8mm -Titanium | 10 |
| Ti.127.410 | CMF – NON Locking EMERGENCY Screw – Dia 2.8mm Length 10mm -Titanium | 10 |
| Ti.127.412 | CMF – NON Locking EMERGENCY Screw – Dia 2.8mm Length 12mm -Titanium | 10 |
| Ti.127.414 | CMF – NON Locking EMERGENCY Screw – Dia 2.8mm Length 14mm -Titanium | 10 |
| Ti.127.416 | CMF – NON Locking EMERGENCY Screw – Dia 2.8mm Length 16mm -Titanium | 10 |
| Ti.127.418 | CMF – NON Locking EMERGENCY Screw – Dia 2.8mm Length 18mm -Titanium | 10 |
| Ti.127.420 | CMF – NON Locking EMERGENCY Screw – Dia 2.8mm Length 20mm -Titanium | 10 |
| 400.174 | Implant Box for Mandibular Maxillofacial Recontruction (2.4mm Thickness) 2.4mm Screws System (Medical Grade Plastic) | 1 |
Designed for precision and efficiency, this CMF Instrument Set includes essential tools like screwdrivers and drill bits. Made from surgical-grade materials, this oral maxillofacial surgical instruments set ensures durability, easy handling, and reliable performance, while its ergonomic design supports comfortable use in maxillofacial procedures.
| Cat No. IS.208 | Description | Units |
|---|---|---|
| XP.916.101 | CMF Straight Quick Coupling Handle | 1 |
| XP.916.102 | CMF Cross Drive Screw Driver Shaft | 1 |
| XP.916.103 | CMF Surgical Elevator 1.5mm Dia. | 1 |
| XP.916.104 | CMF Drill Bit – Plain Shank Dia. 1.1mm X 8.5mm X 48mm Long | 1 |
| XP.916.105 | CMF Drill Bit – Plain Shank Dia. 1.6mm X 12mm X 48mm Long | 1 |
| XP.916.106 | CMF Drill Bit – Plain Shank Dia. 1.9mm X 22mm X 58mm Long | 1 |
| XP.916.107 | CMF Drill Bit – Plain Shank Dia. 1.9mm X 57mm X 82mm Long | 1 |
| XP.916.108 | CMF Temporary Holder HC 2.4mm | 2 |
| XP.916.109 | CMF Universal Drill Guide 1.1/1.6mm | 1 |
| XP.916.110 | CMF Universal Drill Guide 1.6/1.9mm | 1 |
| XP.916.111 | CMF Depth Gauge | 1 |
| 916.120 | CMF Locking Drill Sleeve 1.9mm | 2 |
| 916.121 | CMF Plate Holding Forceps | 1 |
| 400.177 | Instrument Box for Maxillofacial Plating System (Medical Grade Plastic) | 1 |
| IS.210 | Description | Units |
| TI.127.108 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.4mm Length 8mm -Titanium | 8 |
| TI.127.110 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.4mm Length 10mm -Titanium | 8 |
| TI.127.112 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.4mm Length 12mm -Titanium | 8 |
| TI.127.114 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.4mm Length 14mm -Titanium | 8 |
| TI.127.116 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.4mm Length 16mm -Titanium | 8 |
| TI.127.118 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.4mm Length 18mm -Titanium | 8 |
| TI.127.120 | CMF – Cross Drive LOCKING Screw – Self Tapping – Dia 2.4mm Length 20mm -Titanium | 8 |
| TI.127.208 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.4mm Length 8mm -Titanium | 8 |
| TI.127.210 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.4mm Length 10mm -Titanium | 8 |
| TI.127.212 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.4mm Length 12mm -Titanium | 8 |
| TI.127.214 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.4mm Length 14mm -Titanium | 8 |
| TI.127.216 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.4mm Length 16mm -Titanium | 8 |
| TI.127.218 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.4mm Length 18mm -Titanium | 8 |
| TI.127.220 | CMF – Cross Drive NON Locking Screw – Self Tapping – Dia 2.4mm Length 20mm -Titanium | 8 |
| TI.127.308 | CMF – Locking EMERGENCY Screw – Dia 2.8mm Length 8mm -Titanium | 8 |
| TI.127.310 | CMF – Locking EMERGENCY Screw – Dia 2.8mm Length 10mm -Titanium | 8 |
| TI.127.312 | CMF – Locking EMERGENCY Screw – Dia 2.8mm Length 12mm -Titanium | 8 |
| TI.127.314 | CMF – Locking EMERGENCY Screw – Dia 2.8mm Length 14mm -Titanium | 8 |
| TI.127.316 | CMF – Locking EMERGENCY Screw – Dia 2.8mm Length 16mm -Titanium | 8 |
| TI.127.318 | CMF – Locking EMERGENCY Screw – Dia 2.8mm Length 18mm -Titanium | 8 |
| TI.127.320 | CMF – Locking EMERGENCY Screw – Dia 2.8mm Length 20mm -Titanium | 8 |
| TI.127.408 | CMF – NON Locking EMERGENCY Screw – Dia 2.8mm Length 8mm -Titanium | 8 |
| TI.127.410 | CMF – NON Locking EMERGENCY Screw – Dia 2.8mm Length 10mm -Titanium | 8 |
| TI.127.412 | CMF – NON Locking EMERGENCY Screw – Dia 2.8mm Length 12mm -Titanium | 8 |
| TI.127.414 | CMF – NON Locking EMERGENCY Screw – Dia 2.8mm Length 14mm -Titanium | 8 |
| TI.127.416 | CMF – NON Locking EMERGENCY Screw – Dia 2.8mm Length 16mm -Titanium | 8 |
| TI.127.418 | CMF – NON Locking EMERGENCY Screw – Dia 2.8mm Length 18mm -Titanium | 8 |
| TI.127.420 | CMF – NON Locking EMERGENCY Screw – Dia 2.8mm Length 20mm -Titanium | 8 |
| TI.127.500 | Fastening Cap – Titanium | 4 |
| TI.127.508 | Fastening Screw – Dia. 2.5mm Length 8mm – Titanium | 4 |
| TI.127.509 | Fastening Screw – Dia. 2.5mm Length 9mm – Titanium | 4 |
| TI.127.510 | Fastening Screw – Dia. 2.5mm Length 10mm – Titanium | 4 |
| TI.127.511 | Fastening Screw – Dia. 2.5mm Length 11mm – Titanium | 4 |
| TI.127.512 | Fastening Screw – Dia. 2.5mm Length 12mm – Titanium | 4 |
| TI.850.601 | CMF – Locking ANATOMICAL L- Reconstruction Plate 120°Deg. (Thickness 2.4MM) 12 Holes Length 132MM – Right -Titanium | 1 |
| TI.850.602 | CMF – Locking ANATOMICAL L- Reconstruction Plate 120°Deg. (Thickness 2.4MM) 13 Holes Length 138MM – Right -Titanium | 1 |
| TI.850.603 | CMF – Locking ANATOMICAL L- Reconstruction Plate 120°Deg. (Thickness 2.4MM) 14 Holes Length 142MM – Right -Titanium | 1 |
| TI.850.611 | CMF – Locking ANATOMICAL L- Reconstruction Plate 120°Deg. (Thickness 2.4MM) 12 Holes Length 132MM – Left -Titanium | 1 |
| TI.850.612 | CMF – Locking ANATOMICAL L- Reconstruction Plate 120°Deg. (Thickness 2.4MM) 13 Holes Length 138MM – Left -Titanium | 1 |
| TI.850.613 | CMF – Locking ANATOMICAL L- Reconstruction Plate 120°Deg. (Thickness 2.4MM) 14 Holes Length 142MM – Left -Titanium | 1 |
| TI.850.901 | Condyle Block For Anatomical L- Plate – Titanium | 2 |
| 400.179 | Implant Box For Locking Anatomical L- Reconstruction Plate 2.4mm (Medical Grade Plastic) | 1 |
The system includes a complete range of 2.4 mm titanium reconstruction plates, such as straight plates, L-shaped plates, anatomical L plates, and mandibular reconstruction plates, along with compatible locking, non-locking, and emergency screws for comprehensive fixation solutions.
All mandibular plates and screws are manufactured using medical-grade titanium alloy, widely used by leading global manufacturers for its strength, lightweight properties, and excellent biocompatibility.
The system includes:
Locking Straight Reconstruction Plate
Locking L-Reconstruction Plate
Anatomical L-Reconstruction Plate
Non-Locking Straight & L Plates
Mandibular-specific reconstruction plates
These designs help surgeons adapt to different anatomical and surgical needs.
The 2.4 mm system is considered a load-bearing system, providing superior strength and stability compared to smaller systems (1.5 mm / 2.0 mm), making it ideal for mandibular reconstruction and heavy stress regions.
The system supports:
Cross drive locking screws
Cross drive non-locking screws
Emergency screws (locking & non-locking)
This range ensures flexibility during complex surgical procedures.
Compared to international brands, this system offers:
Comparable titanium quality and precision
Competitive pricing for bulk buyers
Wide product range (locking + non-locking + anatomical variants)
Strong export capability
This makes it ideal for distributors seeking cost-effective alternatives without compromising quality.
Yes, Siora Surgicals Pvt. Ltd. offers OEM/private labeling services, enabling distributors to market products under their own brand.
Distributors benefit from:
Bulk supply capability
Custom branding options
Competitive wholesale pricing
Reliable logistics support
MOQ depends on order size, customization, and region. However, flexible MOQ options are available for new and existing distributors.
Packaging and labeling are carried out in ISO Class 7 cleanroom facilities, following ISO 14644 guidelines to maintain product integrity and meet global regulatory requirements.
Locking plates provide angular stability, reduce screw loosening, and maintain fixation even under high load conditions, making them ideal for mandibular fractures and reconstructive surgeries.
Yes, 2.4 mm reconstruction plates are widely used in post-tumor mandibular reconstruction, ensuring structural support and long-term stability.
Yes, titanium reconstruction plates can be easily contoured intraoperatively to match patient anatomy without compromising strength.
If you are interested in our products and want to know more details, please leave message here, we will reply you as soon as we can.