Large Fragment Locking Screws offered by Siora Surgicals Pvt. Ltd. are developed to deliver dependable fixation in demanding trauma cases involving large bones. Commonly used alongside locking plates, these large fragment screws help surgeons achieve better construct stability in fractures of the tibia, femur, and other weight-bearing bones. The threaded locking head is designed to fit securely into the plate, reducing micro-motion and supporting long-term fixation, particularly in weak or osteoporotic bone. Crafted from medical-grade titanium and stainless steel, the screws feature accurate threading and a smooth finish for easier insertion during surgery. With different size options available, they are suitable for various orthopedic trauma and reconstructive procedures where strength and precision matter most.
The locking head mechanism forms a fixed-angle construct with the plate, helping maintain stable fixation even under high mechanical stress.
Precision-engineered threads ensure a firm grip within cortical bone, reducing the chances of loosening after implantation.
Designed to perform effectively in weak or low-density bone conditions where conventional screws may provide limited hold.
Manufactured using medical-grade titanium and stainless steel for enhanced strength, corrosion resistance, and biocompatibility.
The screw design supports controlled insertion and better surgical handling, allowing improved precision during orthopedic procedures.
Available in different diameters and lengths to accommodate various fracture patterns and large bone fixation requirements.
Widely used in the surgical management of femoral fractures requiring stable fixation with locking plate systems.
Suitable for proximal, distal, and shaft fractures of the tibia where enhanced construct stability is essential.
Helps achieve reliable fixation in complex humeral fractures, especially in cases involving poor bone quality.
Recommended for fracture fixation in osteoporotic patients where stronger screw-to-plate locking support is needed.
Used in fractures occurring near joints to maintain alignment and provide controlled stabilization during healing.
Applied in corrective osteotomies and reconstructive surgeries that demand durable and accurate internal fixation.
We manufacture large fragment locking screws in different diameters, lengths, and structural configurations to ensure better stability in various fracture fixation procedures.
Designed for secure fixation with locking plates, this self-tapping screw offers angular stability, strong bone purchase, and reliable performance in trauma surgeries involving large bone fractures. These screws are available in both Hex Drive and Star Drive designs.
| Cat. No. (Stainless Steel) | Length (mm) | Cat. No. (Titanium) |
| 106.314 – 106.390 | 14 – 90 | Ti.106.314 – Ti.106.390 |
Featuring a star drive design for improved torque transmission, this locking screw ensures stable fixation, controlled insertion, and dependable support in complex orthopedic fracture management procedures.
| Cat. No. (Stainless Steel) | Length (mm) | Cat. No. (Titanium) |
| 106.414 – 106.490 | 14 – 90 | Ti.106.414 – Ti.106.490 |
Specially developed for periprosthetic fractures, this screw provides enhanced fixation around implants while maintaining construct stability and reducing the risk of loosening in challenging orthopedic cases.
| Cat. No. (Stainless Steel) | Length (mm) | Cat. No. (Titanium) |
| 106.812 – 106.820 | 12 – 30 | Ti.106.812 – Ti.106.830 |
Engineered for cancellous bone fixation, this fully threaded screw delivers strong holding power, stable locking performance, and smooth insertion in reconstructive and trauma orthopedic procedures.
| Cat. No. (Stainless Steel) | Length (mm) | Cat. No. (Titanium) |
| 110.725 – 110.810 | 25 – 110 | Ti.110.725 – Ti.110.810 |
This star drive cancellous screw offers secure fixation in softer bone structures while supporting enhanced torque control and stable integration with compatible locking plate systems.
| Cat. No. (Stainless Steel) | Length (mm) | Cat. No. (Titanium) |
| 110.925 – 110.998 | 25 – 110 | Ti.110.925 – Ti.110.998 |
Designed with a 16mm threaded portion, this cancellous screw provides dependable fixation, controlled compression, and reliable support in metaphyseal and periarticular fracture treatment procedures.
| Cat. No. (Stainless Steel) | Length (mm) | Cat. No. (Titanium) |
| 108.550 – 108.610 | 40 – 110 | Ti.108.540 – Ti.108.610 |
The taper head design supports better implant seating, while the 16mm thread ensures firm cancellous bone purchase for stable fixation during orthopedic trauma and reconstruction surgeries.
| Cat. No. (Stainless Steel) | Length (mm) | Cat. No. (Titanium) |
| 108.710 – 108.760 | 60 – 110 | Ti.108.710 – Ti.108.760 |
Used in dynamic hip and condylar screw systems, this combination assists controlled compression and stable fixation in proximal femur and distal femoral fracture management.
| Cat. No. (Stainless Steel) | Length (mm) | Cat. No. (Titanium) |
| 168.050 – 168.145 | 50 – 145 | Ti.168.050 – Ti.168.145 |
Manufactured for cortical bone fixation, this self-tapping screw provides strong thread engagement, smooth insertion, and dependable stability in plating procedures for long bone fractures.
| Cat. No. (Stainless Steel) | Length (mm) | Cat. No. (Titanium) |
| 106.214 – 106.274 | 14 – 74 | Ti.106.214 – Ti.106.274 |
The star drive configuration improves torque transfer and minimizes slippage, making this cortical screw suitable for precise and stable fixation in orthopedic trauma surgeries.
| Cat. No. (Stainless Steel) | Length (mm) | Cat. No. (Titanium) |
| 106.120 – 106.160 | 20 – 60 | Ti.106.120 – Ti.106.160 |
Designed for use with locking proximal femur plates, this cannulated screw enables guided insertion and secure fixation in proximal femoral fracture stabilization procedures.
| Cat. No. (Stainless Steel) | Length (mm) | Cat. No. (Titanium) |
| 111.150 – 111.210 | 50 – 110 | Ti.111.150 – Ti.111.210 |
Featuring a longer threaded section, this cannulated cancellous screw offers enhanced fixation in cancellous bone and reliable support during proximal femur fracture treatment surgeries.
| Cat. No. (Stainless Steel) | Length (mm) | Cat. No. (Titanium) |
| 112.160 – 112.210 | 50 – 110 | Ti.112.150 – Ti.112.210 |
This variable angle screw allows flexible screw positioning while maintaining locking stability, helping surgeons address complex fracture patterns with improved fixation versatility.
| Cat. No. (Stainless Steel) | Length (mm) | Cat. No. (Titanium) |
| 106.920 – 106.990 | 20 – 90 | Ti.106.920 – Ti.106.990 |
Engineered for variable angle fixation, this star drive screw supports accurate placement, stable locking performance, and enhanced surgical convenience in orthopedic trauma applications.
| Cat. No. (Titanium) | Length (mm) |
| Ti.106.520 – Ti.106.590 | 20 – 90 |
Developed for cancellous bone fixation, this fully threaded variable angle screw ensures stable construct support and flexible screw angulation in demanding orthopedic procedures.
| Cat. No. (Stainless Steel) | Length (mm) | Cat. No. (Titanium) |
| 111.725 – 111.810 | 25 – 110 | Ti.111.725 – Ti.111.810 |
Combining variable angle technology with star drive efficiency, this cancellous screw offers controlled insertion, reliable fixation, and adaptability in complex fracture reconstruction surgeries.
| Cat. No. (Titanium) | Length (mm) |
| Ti.111.425 – Ti.111.510 | 25 – 110 |
Designed to optimize screw positioning, this spacer helps maintain appropriate implant alignment and supports stable fixation when used with compatible 5.0mm locking head screws.
| Cat. No. (Stainless Steel) | Cat. No. (Titanium) |
| 106.402 | Ti.106.402 |
Siora Surgicals Pvt. Ltd. manufactures a complete range of large fragment screws, including:
Contact us to get the full details!
Our large fragment screws are manufactured using medical-grade titanium and stainless steel, suitable for orthopedic trauma fixation procedures.
Yes, our locking head screws are designed for compatibility with standard large fragment locking plate systems used in trauma and reconstructive surgeries.
Large fragment screws are commonly used in:
Cortical screws are designed for dense cortical bone fixation, while cancellous screws provide better fixation in softer cancellous bone structures.
Yes, complete large fragment screw sets with multiple diameters and lengths are available for hospitals and distributors.
Yes, we offer customized sizes, lengths, and OEM manufacturing options for bulk international orders.
Our orthopedic implants are manufactured under internationally recognized quality management systems for global markets.
Yes, we regularly support bulk procurement requirements for hospitals, distributors, and government orthopedic tenders.
Our systems are preferred for:
If you are interested in our products and want to know more details, please leave message here, we will reply you as soon as we can.