






















Siora Surgicals’ Monolock and Polylock Locking Plates are engineered to provide strong, stable fixation for a wide range of veterinary orthopedic fracture treatments. Designed with precision locking technology, these fixed (monolock) and variable angle (polylock) locking plates help maintain angular stability while minimizing the risk of screw loosening, making them suitable for complex, osteoporotic, and comminuted fractures in animals. Their low-profile design helps reduce soft tissue irritation, while anatomically optimized contours support accurate placement and improved surgical outcomes. Manufactured from high-quality implant-grade materials and developed to meet stringent quality standards, these TPLO locking plate systems enable veterinarians to achieve dependable fixation, promote bone healing, and support faster postoperative recovery in companion and large animals.
Monolock and Polylock plates feature secure locking mechanisms that create a stable screw-plate construct, helping maintain fracture alignment and reducing the risk of fixation failure during the healing process.
The locking design provides superior angular stability, making these veterinary TPLO plates particularly effective for managing complex, comminuted, and osteoporotic fractures in veterinary patients.
Engineered with a low-profile structure, these plates help minimize soft tissue irritation and reduce postoperative discomfort while ensuring reliable fracture fixation.
Manufactured from premium implant-grade stainless steel and titanium, the veterinary locking TPLO plates offer excellent strength, corrosion resistance, and long-term durability to withstand physiological loads.
Available in multiple configurations, Monolock and Polylock locking plates can be used for a wide range of orthopedic procedures, enabling veterinarians to address diverse fracture patterns with confidence.
These veterinary locking TPLO plates are indicated for the stabilization of comminuted fractures where multiple bone fragments require a strong and stable fixation construct to support proper healing.
The locking mechanism provides secure fixation in animals with compromised bone quality, making these veterinary fixed and variable angle locking plates suitable for fractures involving osteoporotic or weakened bone.
These TPLO plates are commonly used for the treatment of metaphyseal fractures, where enhanced angular stability is essential for maintaining alignment and promoting bone union.
Designed to support precise fracture reduction, Polylock locking plates are indicated for periarticular fractures occurring near joints while helping preserve anatomical alignment.
These locking plate systems can also be used in corrective osteotomies and reconstructive orthopedic surgeries, providing reliable fixation throughout the bone healing process.
We manufacture Monolock and Polylock veterinary locking TPLO plates in different sizes and hole configurations to match specific surgical requirements during fracture treatment in small and large animals.
Designed for TPLO procedures in small canine patients, this locking plate provides stable osteotomy fixation, reliable angular stability, and enhanced postoperative support.
| Cat No. (Stainless Steel) | Cat No. (Titanium) |
| 507.101 (Left) | Ti.507.101 (Left) |
| 507.111 (Right) | Ti.507.111 (Right) |
Engineered for small to medium-sized dogs, this TPLO bone plate ensures secure fixation, maintains alignment, and supports predictable bone healing outcomes.
| Cat No. (Stainless Steel) | Cat No. (Titanium) |
| 507.102 (Left) | Ti.507.102 (Left) |
| 507.112 (Right) | Ti.507.112 (Right) |
Offering strong locking fixation for TPLO surgeries, this plate helps achieve stable osteotomy stabilization while reducing the risk of implant loosening.
| Cat No. (Stainless Steel) | Cat No. (Titanium) |
| 507.103 (Left) | Ti.507.103 (Left) |
| 507.113 (Right) | Ti.507.113 (Right) |
Suitable for medium-sized canine patients, this locking TPLO plate provides dependable support, enhanced stability, and consistent fixation throughout recovery.
| Cat No. (Stainless Steel) | Cat No. (Titanium) |
| 507.104 (Left) | Ti.507.104 (Left) |
| 507.114 (Right) | Ti.507.114 (Right) |
Developed for larger dogs undergoing TPLO procedures, this plate delivers robust fixation strength and reliable stabilization for improved surgical outcomes.
| Cat No. (Stainless Steel) | Cat No. (Titanium) |
| 507.105 (Left) | Ti.507.105 (Left) |
| 507.115 (Right) | Ti.507.115 (Right) |
Featuring a broader profile and four-hole configuration, this TPLO plate offers increased fixation options and superior stability for larger canine breeds.
| Cat No. (Stainless Steel) | Cat No. (Titanium) |
| 507.106 (Left) | Ti.507.106 (Left) |
| 507.116 (Right) | Ti.507.116 (Right) |
Designed with polyaxial locking technology, this TPLO plate allows flexible screw placement while ensuring secure fixation and stable osteotomy support.
| Cat No. (Stainless Steel) | Cat No. (Titanium) |
| 507.201 (Left) | Ti.507.201 (Left) |
| 507.211 (Right) | Ti.507.211 (Right) |
This polyaxial locking TPLO plate provides versatile screw angulation, dependable stability, and effective fixation for a wide range of canine patients.
| Cat No. (Stainless Steel) | Cat No. (Titanium) |
| 507.202 (Left) | Ti.507.202 (Left) |
| 507.212 (Right) | Ti.507.212 (Right) |
Engineered for medium-sized dogs, this plate combines locking stability with screw-placement flexibility to support successful TPLO surgical procedures.
| Cat No. (Stainless Steel) | Cat No. (Titanium) |
| 507.203 (Left) | Ti.507.203 (Left) |
| 507.213 (Right) | Ti.507.213 (Right) |
Providing strong fixation and controlled screw angulation, this TPLO plate helps maintain osteotomy alignment and supports reliable postoperative recovery.
| Cat No. (Stainless Steel) | Cat No. (Titanium) |
| 507.204 (Left) | Ti.507.204 (Left) |
| 507.214 (Right) | Ti.507.214 (Right) |
Designed for larger canine patients, this broad polyaxial locking TPLO plate offers enhanced fixation options, superior stability, and flexible screw placement for reliable osteotomy support.
| Cat No. (Stainless Steel) | Cat No. (Titanium) |
| 507.205 (Left) | Ti.507.205 (Left) |
| 507.215 (Right) | Ti.507.215 (Right) |
Yes, Siora provides OEM manufacturing and private labeling services for Veterinary TPLO Locking Plates according to distributor and brand requirements.
Yes, Siora manufactures Veterinary TPLO Plates in medical-grade titanium and stainless steel, depending on customer and market requirements.
Yes, we offer private labeling and customized packaging solutions for veterinary orthopedic implant distributors.
MONOLOCK plates provide fixed-angle stability, while POLYLOCK plates allow multidirectional screw angulation for surgical flexibility.
Yes, our TPLO Plates are specifically designed for canine TPLO procedures and veterinary orthopedic applications.
Siora is trusted for precision manufacturing, global export support, OEM capabilities, consistent quality, and a wide range of veterinary orthopedic implants.